Neon Transformers
Safety :
IEC 61050:1991 Transformers for tubular discharge lamps having a no-load output voltage exceeding 1000 V (generally called neon-transformers). General and safety requirements
EMC:
CISPR 15:2018 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
IEC 61547:2023 Equipment for general lighting purposes. EMC immunity requirements
Performance :
IEC 61347-1:2015+AMD1:2017 CSV Lamp controlgear - Part 1: General and safety requirements
현지 표준
미국
UL 2161 Standard for Safety Neon Transformers and Power Supplies
FCC PART 15.109 Unintentional radiator.
CEC energy efficiency standards Title 20
UL 2388 Standard for Flexible Lighting Products (Ed. 2)
유럽
EN IEC 55015:2019(MAIN)
Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
CISPR 15:2018 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
IEC 61547:2020 Equipment for general lighting purposes - EMC immunity requirements
EN IEC 61000-3-2:2019(MAIN) Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase)
EN IEC 61000-3-2:2019/A1:2021 - Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤16 A per phase)
EN 61000-3-3:2013(MAIN) Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection
EN 61347-1:2015(MAIN) Lamp controlgear - Part 1: General and safety requirements
EN 61347-1:2015/A1:2021 - Lamp controlgear - Part 1: General and safety requirements
EN 61347-2-10:2001(MAIN) Lamp controlgear - Part 2-10: Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes)
EN 61347-2-10:2001/A1:2009 - Lamp controlgear - Part 2-10: Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes)
중국
GB 7000.204-2015: Safety requirements for household and similar electrical appliances - Part 2-204: Particular requirements for neon transformers and power supplies for self-ballasted lamps.
GB/T 18595-2014 Equipment for general lighting purposes-EMC immunity requirements
GB 19149-2003 - Transformers for tubular discharge lamps having a no-load output voltage exceeding 1000V(generally called neon-transformers)--General and safety requirements
일본
JIS C 61000-3-2:2019 Electromagnetic compatibility (EMC) -- Part 3-2: Limits -- Limits for harmonic current emissions (equipment input current <= 20 A per phase)
JIS C 5310:1997 Generic specification of transformers for electronic equipment
JIS C 5311:1994 Testing methods of power transformers for electronic equipment
한국
KS C 4305 Neon transformer
K61050 Transformers for tubular discharge lamps having a no-load output voltage exceeding 1000 V (generally called neon-transformers). General and safety requirements
KS C 9832 Electromagnetic Compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
KS C 9835 Electromagnetic Compatibility (EMC) Requirements for Lighting Equipment
KS C 9815:2019 (Mod CISPR 15:2018) Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
KS C 9547:2020 (Mod IEC 61547:2009) Electromagnetic compatibility (EMC) - Immunity requirements for lighting equipment.
KS C 9610-4-2:2017 (Mod IEC 61000-4-2:2008) Electromagnetic Compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
KS C 9814-1:2020(Mod CISPR 14-1:2016) Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
대만
CNS 14115 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
CNS 2730:2017 Neon light transformers
CNS 14335-2-6 Luminaires - Part 2-6: Particular requirements - Luminaires with built-in Transformers for filament lamps
브라질
NBRIEC61347-2-13 DAY 12/2020-Electronic light control device-Part 2-13: Specific requirements for electronic control devices powered by DC or AC for LED module
ABNT NBRIEC/CISPR15 DE 12/2019 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
ABNT NBRIEC61347-2-12 DE 08/2013 Lamp controlgear - Part 2-12: Particular requirements for d.c or a.c supplied electronic controlgear for discharge lamps (excluding fluorescent lamps)
멕시코
NMX-I-J-324-NYCE-ANCE-2022 Lighting – Integrated light-emitting diode (LED) lamps for general lighting – Safety requirements and test methods
NMX-J-550/3-2-ANCE-2005: ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (DEVICES WITH INPUT CURRENT <=16 A PER PHASE).
NMX-J-550/3-3-ANCE-2005:ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (DEVICES WITH INPUT CURRENT <=16 A PER PHASE).
NOM-001-CRE-SCFI- 2019, Measurement systems for electrical energy - Meters and measurement transformers - Metrological specifications, test methods, and procedure for the evaluation of conformity.
NOM-002-SEDE-ENER-2014, Safety and energy efficiency requirements for distribution transformers.
아르헨티나
IRAM 2250 General principles for safety in electrical installations
IRAM-IEC CISPR 15 Limits and methods of measurement of the characteristics related to radioelectric disturbance of lighting equipment and the like.
오스트레일리아
AS/NZS 61050:1998 Transformers for tubular discharge lamps having a no-load output voltage exceeding 1000 V (generally called neon-transformers) - General and safety requirements
SNZ AS/NZS CISPR 15 2011 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
AS/NZS 61558.2.9:2011 Safety of power transformers, power supplies, reactors and combinations thereof - Part 2.9: Particular requirements for transformers and power supply units for class III handlamps for tungsten filament lamps
남아프리카 공화국
SANS 61000-3-2:2009 (Ed. 3.02) Electromagnetic compatibility (EMC) Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A per phase)
SANS 61000-3-3:2009 (Ed. 2.00) Electromagnetic compatibility (EMC) Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection
SANS 61547:2021 (Ed. 3.00) Equipment for general lighting purposes - EMC immunity requirements
SANS 61347-2-10:2010 (Ed. 1.01) Lamp controlgear Part 2-10: Particular requirements for electronic invertors and convertors for high-frequency operation of cold start tubular discharge lamps (neon tubes)
SANS 61347-1:2021 (Ed. 3.01) Lamp controlgear Part 1: General and safety requirements
사우디아라비아
GSO IEC 61050:2014 Tubular Discharge Lamp Transformers With An Unloaded Output Voltage Exceeding 1000 V (Commonly Called Neon Transformers). General Requirements And Safety Requirements
GSO IEC 61547:2013 Equipment For General Lighting Purposes - Electromagnetic Compatibility (EMC) Impedance Immunity Requirements
GSO IEC/PAS 62717:2013 LED Luminaires For General Lighting - Performance Requirements
유라시아 경제 연합
GOST IEC 61347-2-10-2014 Ballasts for ballasts. Part 2-10. Additional requirements for electronic inverters and converters for high-frequency tubular discharge lamps (neon lamps) cold start
GOST IEC 62442-2-2017 Energy efficiency of ballasts for lamps. Part 2. Ballasts for high-intensity discharge lamps (except fluorescent lamps). Measurement method for determining the effectiveness of a ballast
GOST IEC 62442-3-2017 Energy efficiency of ballasts for lamps. Part 3. Ballasts for halogen lamps and modules with light emitting diodes. Measurement method for determining the effectiveness of a ballast