Safety : 

IEC 62133-2:2017/AMD1:2021  Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems

UN38.3 Transportation Testing for Lithium Batteries and Cells


EMC : -


Performance :

(Temp/ Humid) 

IEC 60068-2-1 Environmental testing - Part 2-1: Tests - Test A: Cold

IEC 60068-2-2 Environmental testing - Part 2-2: Tests - Test B: Dry heat

IEC 60068-2-14 Environmental testing - Part 2-14: Tests - Test N: Change of temperature

IEC 60068-2-30 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

IEC 60068-2-38 Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test

IEC 60068-2-66 Environmental testing - Part 2: Test methods - Test Cx: Damp heat, steady state (unsaturated pressurized vapour)

IEC 60068-2-67 Environmental testing - Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components

IEC 60068-2-78 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state

IEC 60068-3-4 Environmental testing - Part 3-4: Supporting documentation and guidance - Damp heat tests

(Vibration/Impact) 

IEC 60068-2-6 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)

IEC 60068-2-27 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock

IEC 60068-2-31 Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens

IEC 60068-2-53 Environmental testing - Part 2-53: Tests and guidance - Combined climatic (temperature/humidity) and dynamic (vibration/shock) tests

IEC 60068-2-57 Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method

IEC 60068-2-64 Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

IEC60255-21-1 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section One: Vibration tests (sinusoidal)

IEC60255-21-2 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section Two: Shock and bump tests

IEC60255-21-3 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 3: Seismic tests

(IPXX) 

IEC60539-1 Directly heated negative temperature coefficient thermistors - Part 1: Generic specification

IEC60539-2 Directly heated negative temperature coefficient thermistors - Part 2: Sectional specification - Surface mount negative temperature coefficient thermistors

(Altitude) 

IEC 60068-2-12 Environmental testing - Part 3-12: Supporting documentation and guidance - Method to evaluate a possible lead-free solder reflow temperature profile

(Salt spray) 

IEC 60068-2-11 Environmental testing - Part 2-11: Tests - Test Ka: Salt mist

IEC 60068-2-52 Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)


Local Standard


USA

UL 62133-2:2020 - Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes - Safety Requirements for Portable Sealed Secondary Cells, and for Batteries Made from Them, for Use in Portable Applications - Part 2: Lithium Systems

ASTM 15.11 Consumer Products; Vacuum Cleaners

ASTM F2756 Standard Test Method for Determining Energy Consumption of Vacuum Cleaner

UL 2054 Household and Commercial Batteries


Europe

EN 62133-2:2017/A1:2021 - Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems

EN IEC 62885-4:2020(MAIN) Surface cleaning appliances - Part 4: Cordless dry vacuum cleaners for household or similar use - Methods for measuring the performance

EN 61960-3:2017(MAIN) Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for portable applications - Part 3: Prismatic and cylindrical lithium secondary cells, and batteries made from them

EN IEC 61960-4:2020(MAIN) Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for portable applications - Part 4: Coin secondary lithium cells, and batteries made from them

EN 61951-2:2017(MAIN) Secondary cells and batteries containing alkaline or other non acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 2: Nickel-metal hydride

EN 61951-1:2017/A1:2023 - Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 1: Nickel-cadmium


China

GB 31241-2022 Lithium Ion Cells And Batteries Used In Portable Electronic Equipments -- Safety Technical Specification

GB/T 35590-2017 Energy Efficiency Requirements and Energy Efficiency Grades for Small Lithium-ion Batteries for Portable Electronic Devices


Japan

JIS C 62133-2 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary lithium cells and batteries, for use in portable applications - Part 2: Lithium systems

JIS C 62841-2-2:2020 Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery -- Safety -- Part 2-2: Particular requirements for hand-held screwdrivers and impact wrenches


Korea

KC62133-2 Secondary cells and batteries containing alkaline or other non-acid electrolyte - Safety requirements for portable sealed secondary cells,

and for batteries made from them, for use in portable application –Part 2 : Lithium systems

(Temp/ Humid)

KS C IEC60068-2-1 Environmental Testing - Part 2-1: Tests - Test A: Cold

KS C IEC60068-2-2 Environmental Testing - Part 2-2: Tests - Test B: Dry heat

KS C IEC60068-2-14 Environmental testing-Part 2-14:Tests- Test N:Change of temperature

KS C IEC60068-2-30 Environmental testing — Part 2-30: Tests — Test Db: Damp heat, cyclic(12 h+12 h cycle)

KS C IEC60068-2-38 Environmental Testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test

KS C IEC60068-2-66 Environmental testing — Part 2-66: Tests methods — Test Cx: Damp heat, steady state(unsaturated pressurized vapour)

KS C IEC60068-2-67 Environmental testing — Part 2-67: Tests — Test Cy: Damp heat, steady state, accelerated test primarily intended for components

KS C IEC60068-2-78 Environmental testing — Part 2-78: Tests — Test Cab: Damp heat, steady state

KS C IEC60068-3-4 ENVIRONMENTAL TESTING-Part 3-4: Supporting documentation and guidance-Damp heat tests

(Vibration/Impact) 

KS C IEC60068-2-6 Environmental testing-Part 2-6: Tests-Test Fc: Vibration(sinusoidal)

KS C IEC60068-2-27 Environmental testing — Part 2-27: Tests — Test Ea and guidance: Shock

KS C IEC60068-2-31 Environmental testing-Part 2-31:Tests-Test Ec:Rough handling shocks, primarily for equipment-type specimens

KS C IEC60068-2-53 Environmental testing — Part 2-53: Tests and guidance: Combined climatic(temperature/humidity) and dynamic (vibration/shock) tests

KS C IEC60068-2-57 Environmental testing — Part 2-57: Tests — Test Ff: Vibration — Time-history and sine-beat method

KS C IEC60068-2-64 Environmental Testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

KS C IEC60255-21-1 Electrical relays - Part 21 : Vibration, shock, bump and seismic tests on measuring relays and protection equipment- Section 1 : Vibration tests (sinusoidal)

KS C IEC60255-21-2 Electrical relays- Part 21 : Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 2 : Shock and bump tests

KS C IEC60255-21-3 Electrical relays-Part 21:Vibration, shock, bump and seismic tests on measuring relays and protection equipment-Section Three:Seismic tests

(Salt spray) 

KS C IEC60068-2-11 Environmental testing — Part 2-11: Tests — Test Ka: Salt mist

KS C IEC60068-2-52 Environmental testing — Part 2-52: Tests — Test Kb: Salt mist, cyclic(sodium chloride solution)

KS C IEC61960-3: Secondary cells and batteries containing alkaline or other non-acid electrolytes — Secondary lithium cells and batteries for portable applications — Part 3: Prismatic and cylindrical lithium secondary cells, and batteries made from them


Taiwan

CNS 62133-2:2018Secondary cells and batteries containing alkaline or other non-acid electrolytes − Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications − Part 2: Lithium systems  

CNS 14905-2 Hand-held motor-operated electric tools - Safety - Part 2-2: Particular requirements for screwdrivers and impact wrenches

CNS 62841-2-2 Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery – Safety – Part 2-2: Particular requirements for hand-held screwdrivers and impact wrenches

CNS 62841-2-2 Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery – Safety – Part 2-2: Particular requirements for hand-held screwdrivers and impact wrenches


Brasil

IEC 62133-2:2017/AMD1:2021  Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems UN38.3 Transportation Testing for Lithium Batteries and Cells


Mexico

NOM-EM-013-SCFI-2015 Electrical and electronic equipment - Energy efficiency and safety requirements for batteries and accumulators used in portable devices - Specifications and test methods.

NOM-032-ENER-2013 Energy efficiency for self-contained, portable, and stationary batteries


Argentina

IRAM 62401:2018 Cordless hand-held power tools and chargers - Energy efficiency


Australia

AS IEC 62619:2023 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications

AS/NZS 4665.1:2005 - Performance of battery-operated portable appliances - Part 1: General requirements and measuring methods


South Africa

SANS 62133-2:2022 Ed 1 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems.

SANS 61960-3:2019 (Ed. 1.00) Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for portable applications - Part 3: Prismatic and cylindrical lithium secondary cells, and batteries made from them edition 1"

SANS 61960:2012 (Ed. 2.00) Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for portable applications


Saudi Arabia

GSO IEC 62133-2:2021 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety  requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems. 

(Temp/ Humid) 

GSO IEC 60068-2-1:2010 Environmental testing - Part 2-1: Tests - Test A: Cold

GSO IEC 60068-2-2:2010 Environmental testing - Part 2-2: Tests - Test B: Dry heat

GSO IEC 60068-2-38:2015 Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test

GSO IEC 60068-2-66:2015 Environmental testing - Part 2: Test methods - Test Cx: Damp heat, steady state (unsaturated pressurized vapor)

GSO IEC 60068-2-67:2015 Environmental testing - Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components

GSO IEC 60068-2-78:2014 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state

GSO IEC 60068-3-4:2014 Environmental testing - Part 3-4: Supporting documentation and guidance - Damp heat tests

(Vibration/Impact) 

GSO IEC 60068-2-6:2010 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)

GSO IEC 60068-2-53:2014 Environmental Testing - Part 2-53: Tests And Guidance - Combined Climatic (Temperature/Humidity) And Dynamic (Vibration/Shock) Tests

GSO IEC 60068-2-57:2015 Environmental Testing - Part 2-57: Tests - Test Ff: Vibration - Clocking Method

GSO IEC 60255-21-1:2015 Electrical Relays - Part 21: Vibration, Shock, Bump And Seismic Tests On Measuring Relays And Protection Equipment - Section One: Vibration Tests (Sinusoidal)

GSO IEC 60255-21-2:2015 Electrical Relays - Part 21: Vibration, Shock, Bump And Seismic Tests On Measuring Relays And Protection Equipment - Section Two: Shock And Bump Tests

(IPXX) 

GSO IEC 60539-1:2015 Directly Heated Negative Temperature Coefficient Thermistors - Part 1: Generic Specification

GSO IEC 60539-2:2015 Directly Heated Negative Temperature Coefficient Thermistors - Part 2: Sectional Specification - Surface Mount Negative Temperature Coefficient Thermistors

(Altitude) 

GSO IEC/TR 60068-3-12:2015 Environmental Testing - Part 3-12: Supporting Documentation And Guidance - Method To Evaluate A Possible Lead-Free Solder Reflow Temperature Profile

(Salt spray) 

GSO IEC 60068-2-11:2015 Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist

GSO IEC 60068-2-52:2014 Environmental Testing – Part 2-52: Tests – Test Kb: Salt Mist, Cyclic (Sodium Chloride Solution)


EAEU

GOST R IEC 62133-2-2019 Secondary cells and batteries containing alkaline or other non-acid electrolytes. Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications. Part 2. Lithium systems

GOST R IEC 62637-1-2015 Battery charging interface for small handheld multimedia devices. Part 1. Two-millimeter barrel interface"

GOST R IEC 62637-2-2015 Battery charging interface for small handheld multimedia devices. Part 2. Two-millimeter barrel type interface conformance testing

GOST R IEC 61960-3-2019 Batteries and rechargeable batteries containing alkaline or other non-acid electrolytes. Lithium batteries and batteries for portable applications. Part 3. Prismatic and cylindrical lithium batteries and batteries"