ESS (Energy Storage Systems)
ESS (Energy Storage Systems)
Safety :
IEC 62133-2:2017/AMD1:2021 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems
UN38.3 Transportation Testing for Lithium Batteries and Cells
EMC : -
Performance :
(Temp/ Humid)
IEC 60068-2-1 Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2 Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-14 Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-30 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-38 Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
IEC 60068-2-66 Environmental testing - Part 2: Test methods - Test Cx: Damp heat, steady state (unsaturated pressurized vapour)
IEC 60068-2-67 Environmental testing - Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components
IEC 60068-2-78 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC 60068-3-4 Environmental testing - Part 3-4: Supporting documentation and guidance - Damp heat tests
(Vibration/Impact)
IEC 60068-2-6 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-27 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-31 Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens
IEC 60068-2-53 Environmental testing - Part 2-53: Tests and guidance - Combined climatic (temperature/humidity) and dynamic (vibration/shock) tests
IEC 60068-2-57 Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method
IEC 60068-2-64 Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
IEC60255-21-1 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section One: Vibration tests (sinusoidal)
IEC60255-21-2 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section Two: Shock and bump tests
IEC60255-21-3 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 3: Seismic tests
(IPXX)
IEC60539-1 Directly heated negative temperature coefficient thermistors - Part 1: Generic specification
IEC60539-2 Directly heated negative temperature coefficient thermistors - Part 2: Sectional specification - Surface mount negative temperature coefficient thermistors
(Altitude)
IEC 60068-2-12 Environmental testing - Part 3-12: Supporting documentation and guidance - Method to evaluate a possible lead-free solder reflow temperature profile
(Salt spray)
IEC 60068-2-11 Environmental testing - Part 2-11: Tests - Test Ka: Salt mist
IEC 60068-2-52 Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
Local Standard
USA
UL 62133-2:2020 - Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes - Safety Requirements for Portable Sealed Secondary Cells, and for Batteries Made from Them, for Use in Portable Applications - Part 2: Lithium Systems
UL 9540 Energy Storage System (ESS) Requirements
IEEE 1547-2018 IEEE Standard for Interconnection and Interoperability of Distributed Energy Resources with Associated Electric Power Systems Interfaces
CEC Building Energy Efficiency Standards - Title 24
Protocol for Uniformly Measuring and Expressing the Performance of Energy Storage Systems
IEEE 1188-2005 IEEE Recommended Practice for Maintenance, Testing, and Replacement of Valve-Regulated Lead-Acid (VRLA) Batteries for Stationary Applications
Europe
EN IEC 62933-2-1:2018(MAIN) Electrical energy storage (EES) systems - Part 2-1: Unit parameters and testing methods - General specification
EN IEC 62933-5-2:2020(MAIN) Electrical energy storage (EES) systems - Part 5-2: Safety requirements for grid-integrated EES systems - Electrochemical-based systems
EN 61427-2:2015(MAIN) Secondary cells and batteries for renewable energy storage - General requirements and methods of test - Part 2: On-grid applications
EN 62133-2:2017/A1:2021 - Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems
China
GB 31241-2022 Lithium Ion Cells And Batteries Used In Portable Electronic Equipments -- Safety Technical Specification
GB/T 34678-2017 Technical requirements for energy storage system in wind power and photovoltaic power generation
Japan
JIS C 62133-2 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary lithium cells and batteries, for use in portable applications - Part 2: Lithium systems
JIS C 4441:2021 Electrical energy storage (EES) systems -- Safety requirements for grid-integrated EES systems -- Electrochemical-based systems
JIS C 4411-3:2004 Uninterruptible power systems (UPS) Part 3: Method of specifying the performance and test requirements
Korea
KC62133-2 Secondary cells and batteries containing alkaline or other non-acid electrolyte - Safety requirements for portable sealed secondary cells,
and for batteries made from them, for use in portable application –Part 2 : Lithium systems
(Temp/ Humid)
KS C IEC60068-2-1 Environmental Testing - Part 2-1: Tests - Test A: Cold
KS C IEC60068-2-2 Environmental Testing - Part 2-2: Tests - Test B: Dry heat
KS C IEC60068-2-14 Environmental testing-Part 2-14:Tests- Test N:Change of temperature
KS C IEC60068-2-30 Environmental testing — Part 2-30: Tests — Test Db: Damp heat, cyclic(12 h+12 h cycle)
KS C IEC60068-2-38 Environmental Testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
KS C IEC60068-2-66 Environmental testing — Part 2-66: Tests methods — Test Cx: Damp heat, steady state(unsaturated pressurized vapour)
KS C IEC60068-2-67 Environmental testing — Part 2-67: Tests — Test Cy: Damp heat, steady state, accelerated test primarily intended for components
KS C IEC60068-2-78 Environmental testing — Part 2-78: Tests — Test Cab: Damp heat, steady state
KS C IEC60068-3-4 ENVIRONMENTAL TESTING-Part 3-4: Supporting documentation and guidance-Damp heat tests
(Vibration/Impact)
KS C IEC60068-2-6 Environmental testing-Part 2-6: Tests-Test Fc: Vibration(sinusoidal)
KS C IEC60068-2-27 Environmental testing — Part 2-27: Tests — Test Ea and guidance: Shock
KS C IEC60068-2-31 Environmental testing-Part 2-31:Tests-Test Ec:Rough handling shocks, primarily for equipment-type specimens
KS C IEC60068-2-53 Environmental testing — Part 2-53: Tests and guidance: Combined climatic(temperature/humidity) and dynamic (vibration/shock) tests
KS C IEC60068-2-57 Environmental testing — Part 2-57: Tests — Test Ff: Vibration — Time-history and sine-beat method
KS C IEC60068-2-64 Environmental Testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
KS C IEC60255-21-1 Electrical relays - Part 21 : Vibration, shock, bump and seismic tests on measuring relays and protection equipment- Section 1 : Vibration tests (sinusoidal)
KS C IEC60255-21-2 Electrical relays- Part 21 : Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 2 : Shock and bump tests
KS C IEC60255-21-3 Electrical relays-Part 21:Vibration, shock, bump and seismic tests on measuring relays and protection equipment-Section Three:Seismic tests
(Salt spray)
KS C IEC60068-2-11 Environmental testing — Part 2-11: Tests — Test Ka: Salt mist
KS C IEC60068-2-52 Environmental testing — Part 2-52: Tests — Test Kb: Salt mist, cyclic(sodium chloride solution)
Taiwan
CNS 62133-2:2018Secondary cells and batteries containing alkaline or other non-acid electrolytes − Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications − Part 2: Lithium systems
CNS 62933-2-1 Electrical Energy Storage Systems (EESS) − Part 2-1: Unit parameters and testing methods − General specification
CNS 62933-3-1 Electrical Energy Storage Systems (EESS) − Part 3-1: Planning and performance assessment of electrical energy storage systems − General specification
CNS 63056 Secondary cells and batteries containing alkaline or other non-acid electrolytes − Safety requirements for secondary lithium cells and batteries for use in electrical Energy Storage Systems
CNS 62933-4-1 Electrical Energy Storage Systems (EESS) − Part 4-1: Guidance on environmental issues − General specification
Brasil
IEC 62133-2:2017/AMD1:2021 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems UN38.3 Transportation Testing for Lithium Batteries and Cells
ABNT NBR16641 DE 02/2023 Thermosolar reservoirs — Specific requirements for use in solar thermal energy storage systems — Mechanical and electrical safety
Mexico
NOM-EM-013-SCFI-2015 Electrical and electronic equipment - Energy efficiency and safety requirements for batteries and accumulators used in portable devices - Specifications and test methods.
NOM-016-ENER-2016 Energy efficiency and safety requirements for energy storage systems
Argentina
IRAM 62403:2018 Electrical energy storage systems - Energy efficiency
Australia
AS IEC 62619:2023 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications
AS/NZS 4755.3.5:2016 Demand response capabilities and supporting technologies for electrical products, Part 3.5: Interaction of demand response enabling devices and electrical products - Operational instructions and connections for grid-connected electrical energy storage (EES) systems
South Africa
SANS 62133-2:2022 Ed 1 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems.
SANS 6469-1:2010 (Ed. 1.00) Electrically propelled road vehicles - Safety specifications Part 1: On-board rechargeable energy storage system (RESS)
Saudi Arabia
GSO IEC 62133-2:2021 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems.
(Temp/ Humid)
GSO IEC 60068-2-1:2010 Environmental testing - Part 2-1: Tests - Test A: Cold
GSO IEC 60068-2-2:2010 Environmental testing - Part 2-2: Tests - Test B: Dry heat
GSO IEC 60068-2-38:2015 Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test
GSO IEC 60068-2-66:2015 Environmental testing - Part 2: Test methods - Test Cx: Damp heat, steady state (unsaturated pressurized vapor)
GSO IEC 60068-2-67:2015 Environmental testing - Part 2-67: Tests - Test Cy: Damp heat, steady state, accelerated test primarily intended for components
GSO IEC 60068-2-78:2014 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
GSO IEC 60068-3-4:2014 Environmental testing - Part 3-4: Supporting documentation and guidance - Damp heat tests
(Vibration/Impact)
GSO IEC 60068-2-6:2010 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
GSO IEC 60068-2-53:2014 Environmental Testing - Part 2-53: Tests And Guidance - Combined Climatic (Temperature/Humidity) And Dynamic (Vibration/Shock) Tests
GSO IEC 60068-2-57:2015 Environmental Testing - Part 2-57: Tests - Test Ff: Vibration - Clocking Method
GSO IEC 60255-21-1:2015 Electrical Relays - Part 21: Vibration, Shock, Bump And Seismic Tests On Measuring Relays And Protection Equipment - Section One: Vibration Tests (Sinusoidal)
GSO IEC 60255-21-2:2015 Electrical Relays - Part 21: Vibration, Shock, Bump And Seismic Tests On Measuring Relays And Protection Equipment - Section Two: Shock And Bump Tests
(IPXX)
GSO IEC 60539-1:2015 Directly Heated Negative Temperature Coefficient Thermistors - Part 1: Generic Specification
GSO IEC 60539-2:2015 Directly Heated Negative Temperature Coefficient Thermistors - Part 2: Sectional Specification - Surface Mount Negative Temperature Coefficient Thermistors
(Altitude)
GSO IEC/TR 60068-3-12:2015 Environmental Testing - Part 3-12: Supporting Documentation And Guidance - Method To Evaluate A Possible Lead-Free Solder Reflow Temperature Profile
(Salt spray)
GSO IEC 60068-2-11:2015 Basic environmental testing procedures - Part 2-11: Tests - Test Ka: Salt mist
GSO IEC 60068-2-52:2014 Environmental Testing – Part 2-52: Tests – Test Kb: Salt Mist, Cyclic (Sodium Chloride Solution)
EAEU
GOST R IEC 62133-2-2019 Secondary cells and batteries containing alkaline or other non-acid electrolytes. Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications. Part 2. Lithium systems
GOST R IEC 62932-2-2-2022 Flow battery energy storage systems. Part 2-2. Safety requirements and test methods
GOST R IEC 62932-2-1-2022 Flow battery energy storage systems. Part 2-1. Test methods for determining performance characteristics
GOST R 58092.3.3-2023 Electric energy storage systems. Planning and performance assessment. Energy intensive and backup power applications
GOST R 58092.3.2-2023 Electric energy storage systems. Planning and performance assessment. Power intensive applications and renewable energy sources integration
GOST R 58092.2.2-2023 Electric energy storage systems. Unit parameters and testing methods. Application and performance testing